HyperTechはオーバーサンプリングの事ではないよ
91: 2023/07/19(水)02:30 ID:lKjleQ92(2/2) AAS
New Hyper engine

Our standard compressors run at 22kHz regardless of sample rate or oversampling; this implies that the reduction, attack, and release curves are not calculated for every sample but for every 'n' samples, where 'n' depends on the sample rate. For example, on fast transients, the input level is evaluated correctly; however, the reduction is calculated after 'n' samples, so the signal containing the transient is not compressed in time, and the transient "escapes" compression.

This new Hyper compression tech calculates the amount of compression and the attack and release curves at each sample, so compression is applied immediately and no longer after 'n' samples.